Adri Broekman - Stable isotope dilution analysis by thermal ionization mass spectrometry (II): The determination of cadmium and copper

Version 1

      Publication Details (including relevant citation   information):

      Fresenius' Zeitschrift für analytische Chemie January 1984,   Volume 318, Issue 6, pp 398–401 

      Abstract:

    The combination of stable isotope dilution analysis (SIDA) and thermal ionization mass spectrometry (TIMS) is in use for lead and uranium determination at milligram per kilogram levels for over 20 years.

    However, several other elements can also be determined accurately by SIDA/TIMS. In this study the determinations of cadmium and copper are described. Details of the digestion, electrochemical and ion-exchange separations and the loading of the elements on a filament are given. The advantages of the SIDA/TIMS technique are shown and illustrated with results for several certified reference materials.

      Address (URL):